Easy to use mm wave low loss dielectric test
- Ideal for evaluating low loss dielectric materials with tan δ 0.01 or less
- Easy and reproducible dielectric material measurement in millimeter wave band with excellent fixture design
- Unique excitation mechanism extends the upper limit frequency to 80 GHz
The millimeter wave material market has changed drastically by 5G and automotive radar, which requires an easy to use and accurate material test solution at mm wave frequencies. Answering this requirement, our split cylinders are very widely used in the growing markets.
Example System Configuration

- Keysight Streamline USB Vector Network Analyzer P5007A (44 GHz)
- Split cylinder 28 GHz : CR-728
- Software for split cylinder : CR-MA
- Cables 1.85 mm and 2.92mm adapter
- Windows PC
Watch and Learn: Split Cylinder Resonator
Simple to Use, Powerful in Performance — See It in Action!
Temp & Humidity dependency measurement system
- Temperature Testing: -50°C to 150°C with 10–80 GHz split-cylinder.
- Temp & Humidity Testing: 10–40 GHz range using an environmental chamber.
- Fully Automated: PC controls VNA and chamber — just input settings.
- Ready to Use: Built-in expertise for easy, reliable results.
Reliable Dielectric Evaluation Across Wide Temperature Ranges
As performance demands on materials continue to rise, verifying their behavior under actual operating conditions has become increasingly critical. However, performing reliable permittivity measurements over a wide temperature range has long been a technical challenge. Drawing on expertise gained from evaluating over 50 different samples, we developed a system that delivers meaningful results immediately after installation.
Example System Configuration

- Keysight Streamline USB Vector Network Analyzer P5007A (44 GHz)
- Split cylinder 28 GHz CR-728-TH
- Temp & Hum test software : CR-TH
- Cable set for temp & hum test : CR-TC-CB
- Windows PC
- Chamber (Espec) : SH-662
Measurement Examples
Sample size
Recommended sample size [mm]
Frequency | 短辺 | 長辺 |
---|---|---|
10 GHz | 62 | 75 |
20 - 80 GHz | 34 | 45 |
Recommended thickness
We recommend about 100μm. The chart shows the approximate maximum thickness that can be measured with the split cylinder resonators. The larger the permittivity and the higher the frequency, the thinner the sample needs to be. If the loss is more than about 0.01, a thinner sample may be required. On the other hand, it should be noted that the thinner the sample (e.g. 10μm), the more noticeable the error in thickness measurement becomes, and consequently the larger the error in permittivity measurement becomes. For details, please contact us.

Products
for room temperature
product number | product name | connection |
---|---|---|
CR-710 | Split Cylinder 10 GHz | 2.92mm(f) |
CR-720 | Split Cylinder 20 GHz | 2.92mm(f) |
CR-724 | Split Cylinder 24 GHz | 2.92mm(f) |
CR-728 | Split Cylinder 28 GHz | 2.92mm(f) |
CR-735 | Split Cylinder 35 GHz | 2.92mm(f) |
CR-740 | Split Cylinder 40 GHz | 2.92mm(f) |
CR-750 | Split Cylinder 50 GHz | 2.4mm(f) |
CR-760 | Split Cylinder 60 GHz | 1.85mm(f) |
CR-780 | Split Cylinder 80 GHz | 1mm(f) |
For temperature & humidity test
product number | product name |
---|---|
CR-710-TC | Split Cylinder 10 GHz for Temp test |
CR-720-TC | Split Cylinder 20 GHz for Temp test |
CR-724-TC | Split Cylinder 24 GHz for Temp test |
CR-728-TC | Split Cylinder 28 GHz for Temp test |
CR-735-TC | Split Cylinder 35 GHz for Temp test |
CR-740-TC | Split Cylinder 40 GHz for Temp test |
CR-750-TC | Split Cylinder 50 GHz for Temp test |
CR-760-TC | Split Cylinder 60 GHz for Temp test |
CR-780-TC | Split Cylinder 80 GHz for Temp test |
CR-710-TH | Split Cylinder 10 GHz for Temp & Hum test |
CR-720-TH | Split Cylinder 20 GHz for Temp & Hum test |
CR-728-TH | Split Cylinder 28 GHz for Temp & Hum test |
CR-740-TH | Split Cylinder 40 GHz for Temp & Hum test |